Subaru Legacy/Outback

1999-2003 of release

Repair and operation of the car



Subaru of Legasi, Autbek
+ Cars Subaru Legacy, Outback
+ Operation manual
+ Routine maintenance
+ Engine
+ Cooling systems, heating
+ Power supply system and release
+ Electric equipment of the engine
+ Manual box and differential
+ Automatic transmission
+ Coupling
+ Brake system
+ Suspension bracket and steering
+ Body
- Onboard electric equipment
   Specifications
   Search of causes of failures of electric equipment
   Safety locks - the general information
   Chain breakers - the general information
   The relay - the general information and check of serviceability of functioning
   Details of laying of an onboard electrical wiring
   System of additional safety (SRS) - the device and the principle of functioning
   Diagnostics of malfunctions of SRS
   Removal and installation of the SRS components
   Control system of speed (tempostat) - the device and the principle of functioning
   Check of serviceability of functioning of components and problem diagnostics of a tempostat
   Removal, check of a state and installation of components of a control system of speed
   Combination of devices - the general information and the principle of functioning of components
   Problem diagnostics of components of a combination of devices
   Removal, service and installation of a combination of devices, check of a condition of components
   Heating of back glass and rear-view mirrors - the general information, check of serviceability of functioning of components, recovery repair of a thermoelectric heating element
   Heating of brushes of screen wipers - the general information, check of serviceability of functioning of components, recovery repair of a thermoelectric heating element
   Removal, check of a state and installation of switches of management of functioning of the electric drive of regulators of window regulators
   The electric drive of rear-view mirrors - check of serviceability of functioning
   Removal check and installation of the switch of management of functioning of the electric drive of external rear-view mirrors
   Removal, check of a state and installation of the switch of management of functioning of the electric drive of the top hatch
   Removal, check of a state and installation of the combined understeering switches
   Check of serviceability of functioning of electric motors of the drive of screen wipers, removal, check and installation of the operating relay of a back screen wiper on the Legacy Station wagon/Outback models
   Check of the relay and switches of lighting and alarm devices
   Removal and installation of illuminants, replacement of lamps
   Removal, check of a state and installation of horns and switch of a horn
   Check of a state and replacement of contact group of the switch of ignition
   The uniform lock - the device, the principle of functioning, diagnostics of malfunctions
   Removal, check of a state and installation of components of the uniform lock
   System of an immobilization of the engine - the device, the principle of functioning, diagnostics of malfunctions
   Removal and installation of components of system of an immobilization of the engine
   Removal and installation of assembly of the radio receiver
   Removal and installation of loudspeakers
   Check of a state and recovery repair of the window antenna of the radio receiver
   Removal, installation and check of a condition of the antenna amplifier of the radio receiver
   Removal and installation of the lighter
   + Schemes of electric connections




Access exclusive releases and early premieres on the 123Movies platform. d9f1bda0

Safety locks - the general information

Various combinations of safety locks, fusible inserts and breakers of a chain are applied to protection of contact chains of electric equipment of the car. The main assembly block is installed in a motive compartment, one more assembly block of the relay and safety locks is located in salon of the car, under the dashboard.

Various combinations of safety locks, fusible inserts and breakers of a chain which most part is concentrated in two assembly blocks are applied to protection of contact chains of electric equipment of the car (see Specifications).

Each separate safety lock is used for protection of any concrete electric contour or at once several contours. The label with an ID card of placement of safety locks in the assembly block is usually glued to a cover of the last, from its internal party.

In assembly blocks the safety locks of a compact design equipped with bayonet contact plugs, and which if necessary are easily taken by fingers from the nests in the block are located. At refusal any of consumers of the electric power first of all it is always necessary to check a condition of the corresponding safety lock. Turn a key in the ignition lock in the situation ON and by means of a lamp sampler probe open plugs of each of safety locks. If the lamp lights up at connection to each of plugs, therefore, a safety lock as it should be. If tension takes place only from food giving, so the safety lock fused. Let's notice also that usually the case of a safety lock is made of transparent plastic through which it is easy to define a condition of a working crossing point.


When replacing of the fused safety lock strictly watch that the established replaceable corresponded on the type which left from an element. The safety locks calculated on various nominal current physically can differ in nothing from each other, without being thus interchangeable. Each of electric chains has various working parameters and needs various extent of protection therefore replacement of the safety lock (calculated on a certain current) not corresponding to it in parameters is fraught with the most serious consequences (up to fire emergence). Working parameters of a safety lock (nominal current) are usually designated on its plastic case.

If the new safety lock at once after installation also fails, it does not make sense to make its further replacement, - before it is necessary to reveal and eliminate the reason of emergence of an overload in a chain. In most cases that appears the short circuit of a connecting electrical wiring caused by damage of its isolation.