1. Remove the air cleaner case (see the Head of the Power supply system and release). 2. Disconnect from the executive cylinder a hydraulic hose, - at once to a zakuporta the open ends of a hose and the reception union in order to avoid hit of dirt in a hydraulic path.
|
3. Turn out fixing screws and remove the executive cylinder from RKPP case.
Efforts of a tightening of threaded connections, Nanometer
T1: 18 T2: 37 |
4. Attentively study a condition of the cylinder, - in case of detection of mechanical damages or signs of development of leaks, assembly of the cylinder is subject to replacement. 5. Installation is made as it should be, the return to an order of dismantle of components. Track that all fixture was tightened with the demanded effort.
|
Before installation the surface of a rod of the cylinder contacting to the coupling switching off lever should be greased with greasing like Sunlight 2: P/N 003602010. |
6. Remove from the cylinder air (see the Section Removal of Air from a hydraulic path of the drive of switching off of coupling) and check serviceability of functioning of coupling. |