Subaru Legacy/Outback

1999-2003 of release

Repair and operation of the car



Subaru of Legasi, Autbek
+ Cars Subaru Legacy, Outback
+ Operation manual
+ Routine maintenance
+ Engine
- Cooling systems, heating
   Specifications
   + engine Cooling system
   + Systems of heating/ventilation/air conditioning
+ Power supply system and release
+ Electric equipment of the engine
+ Manual box and differential
+ Automatic transmission
+ Coupling
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment




d9f1bda0

Specifications

Cooling system

Type

Volume of cooling liquid

See the Head Routine maintenance

Water pump

Type

Centrifugal, rotor type

Account characteristic of the water pump

 

L models 2.0 and 2.5

 

At 85 °C and 760 rpm

20 l/min

At 85 °C and 3000 rpm

100 l/min

At 85 °C and 6000 rpm

200 l/min

Models of 3.0 l

At 80 °C and 5500 rpm

320 l/min

Diameter of a driving pulley (l models 2.0 and 2.5), mm

60

Quantity of teeths of a driving asterisk (model of 3.0 l)

22

Diameter of a rotor (gear wheel), mm

L models 2.0 and 2.5

76

Models of 3.0 l 73.

2

Number of shovels of a rotor

L models 2.0 and 2.5

8

Models of 3.0 l

6

Gap of landing of a rotor in a working chamber (l models 2.0 and 2.5), mm

Nominal rate

0.5 ÷ 0.7

Limit admissible value

1.0

Radial beating of a rotor (l models 2.0 and 2.5), mm

0.5

Thermostat

Type

Voskozapolnenny

Temperature of the beginning of opening, °C

76 ÷ 80

Temperature of full opening, °C

91

Height of raising of the valve, mm

9.0

Diameter of the valve through passage, mm

35

Electric fans of the cooling system

Power consumption of an electric motor, W

L models 2.0 and 2.5

Main fan

75

Auxiliary fan

75

Models of 3.0 l

Main fan

120

Auxiliary fan

120

Diameter of a krylchatka, mm

L models 2.0 and 2.5

Main fan

300

Auxiliary fan

300

Models of 3.0 l

Main fan

320

Auxiliary fan

320

Number of blades

L models 2.0 and 2.5

Main fan

5

Auxiliary fan

4

Models of 3.0 l

Main fan

5

Auxiliary fan

7

Radiator

Type

Tight, with the falling stream

Heat exchanger type

With corrugated plates

Sizes of the heat exchanger, mm

L models 2.0 and 2.5

691.5 ÷ 340 ÷ 16

Models of 3.0 l

699 ÷ 349 ÷ 27

Pressure of operation of the safety valve which is built in in a cover, kPa

The top

Nominal rate

Over 108 ± 15

Limit admissible value

83

The lower

It is lower than-1.0 ÷-4.9

Volume of a broad tank, l

L models 2.0 and 2.5

0.5

Models of 3.0 l

2001 vyp.

0.45

2002 vyp.

0.5

Heating of salon

The maximum power of return of the heat exchanger (at a difference of temperatures of cooling liquid and the entering air in 65 °C and a consumption of liquid of 360 l/h), kW

5

Air consumption in the mode of ventilation and maximum warming up, m3

300

The maximum consumption of air (heating is disconnected, the circulation mode, the 4th high-speed mode of the fan), m3

500

Sizes of the heat exchanger, mm

193.5 ÷ 152 ÷ 35.0

Heater fan drive electric motor type

Magnetic, with a power not less than 200 W at supply voltage of 12 V

Fan type

Centrifugal (SIROCCO)

Sizes of a krylchatka (diameter of ÷ width), mm

150? 75

Air conditioning system

General parameters

Oil coolant type

HFC-134a (CH2FCF3)

Volume of coolant, kg

0.65 ± 0.05

Refrigerating capacity, kW

5.2

Idling turns at included To/in (MPFI power supply system)

850 ± 100

Compressor

Compressor type

Rotary, with five shovels and with the fixed volume (DKV-14G)

Expense, cm3/turnover

140

Maximum admissible frequency of rotation, rpm

7000

Magnetic coupling of coupling

Type

Dry, one-disk with the drive from a V-shaped belt

Type of a driving belt

L models 2.0 and 2.5

Mnogoruchyeva 4 PK

Models of 3.0 l

Mnogoruchyeva 6 PK

Power consumption, W

38

Diameter of a driving pulley, mm

125

Transfer relations of the belt drive

1.064:1

Condenser

Type

The multiline

Heat exchanger type

With corrugated plates

Area of a front surface of the heat exchanger, sq.m

0.22

Thickness of the heat exchanger, mm

21

Effektivnaya Square of the heat exchanger, sq.m

6.52

Receiver dehumidifier

Effective internal volume, cm3

250

Broad valve

Type

With the built-in equalizer

Evaporator

Type

The single-chamber

Sizes, mm

235? 224? 60

Air supply fan

Type

Centrifugal (SIROCCO)

Sizes (outer diameter of ÷ width), mm

150 ÷ 75

Power consumption (at food in 12 V), W

220

Sensor switch of pressure (two-level)

Working pressure of operation of the low pressure sensor switch, kPa

In C — Vykl

177 ± 25

Vykl — Vkl

216 1

Working pressure of operation of the high-pressure sensor switch, kPa

In C — Vykl

2942 ± 196

Overlap

588 ± 196

Amplifier of thermocontrol

Activation temperature (air at the exit from the evaporator)

Efforts of a tightening of threaded connections, Nanometer

 Efforts of a tightening of threaded connections are given also in the text of the Head and on sopr. illustrations.

Bolts of fastening of a cover of the thermostat

6.4

Bolts of fastening of casings of fans of the cooling system

4.9

Fastening bolts/nut a krylchatok of fans to electric motors

L models 2.0 and 2.5

3.4

Models of 3.0 l

7.5

Bolts of fastening of electric motors of fans

4.4

Bolts of fastening of a radiator

L models 2.0 and 2.5

18

Models of 3.0 l

12

Bolts of fastening of a broad tank

4.9

Bolts of fastening of lines of a path of cooling of ATF

12

Boats of fastening of the water pump

L models 2.0 and 2.5

First stage

12

Second stage

12

L models 2.0 and 2.5

6.4

Bolts and nuts of fastening of sections of a casing of a heater

7.35

Bolts of fastening of the K/V compressor to basic arms

28.9

Bolts of fastening of basic arms of fastening of the K/V compressor

35

Bolts of fastening of a cover of a belt of the drive of the compressor

7.4

Nut of fastening of a pulley of the drive of the K/V compressor

23

Bolts of fastening of an arm of a tension roller of a belt of the drive of the K/V compressor

23

Bolts of fastening of the condenser

7.4

Screws of fastening of a receiver dehumidifier

7.4

Nipple bolts of fastening of lines of a refrigerator path to the K/V compressor

15

Nipple bolt of fastening of the line of a refrigerator path to a receiver dehumidifier To/in

7.4

Nipple bolt of fastening of the line of a refrigerator path to the K/V condenser

15