Cooling system |
Type |
Volume of cooling liquid | See the Head Routine maintenance
|
Water pump |
Type | Centrifugal, rotor type |
Account characteristic of the water pump | |
L models 2.0 and 2.5 | |
At 85 °C and 760 rpm | 20 l/min
|
At 85 °C and 3000 rpm | 100 l/min
|
At 85 °C and 6000 rpm | 200 l/min
|
Models of 3.0 l |
|
At 80 °C and 5500 rpm | 320 l/min
|
Diameter of a driving pulley (l models 2.0 and 2.5), mm | 60
|
Quantity of teeths of a driving asterisk (model of 3.0 l) | 22
|
Diameter of a rotor (gear wheel), mm |
L models 2.0 and 2.5 | 76
|
Models of 3.0 l 73. | 2
|
Number of shovels of a rotor |
L models 2.0 and 2.5 | 8
|
Models of 3.0 l | 6
|
Gap of landing of a rotor in a working chamber (l models 2.0 and 2.5), mm |
Nominal rate | 0.5 ÷ 0.7
|
Limit admissible value | 1.0
|
Radial beating of a rotor (l models 2.0 and 2.5), mm | 0.5
|
Thermostat |
Type | Voskozapolnenny
|
Temperature of the beginning of opening, °C | 76 ÷ 80
|
Temperature of full opening, °C | 91
|
Height of raising of the valve, mm | 9.0
|
Diameter of the valve through passage, mm | 35
|
Electric fans of the cooling system |
Power consumption of an electric motor, W |
L models 2.0 and 2.5 |
Main fan | 75
|
Auxiliary fan | 75
|
Models of 3.0 l |
Main fan | 120
|
Auxiliary fan | 120
|
Diameter of a krylchatka, mm |
L models 2.0 and 2.5 |
Main fan | 300
|
Auxiliary fan | 300
|
Models of 3.0 l |
Main fan | 320
|
Auxiliary fan | 320
|
Number of blades |
L models 2.0 and 2.5 |
Main fan | 5
|
Auxiliary fan | 4
|
Models of 3.0 l |
Main fan | 5
|
Auxiliary fan | 7
|
Radiator |
Type | Tight, with the falling stream
|
Heat exchanger type | With corrugated plates
|
Sizes of the heat exchanger, mm |
L models 2.0 and 2.5 | 691.5 ÷ 340 ÷ 16
|
Models of 3.0 l | 699 ÷ 349 ÷ 27
|
Pressure of operation of the safety valve which is built in in a cover, kPa |
The top |
|
Nominal rate | Over 108 ± 15
|
Limit admissible value | 83
|
The lower | It is lower than-1.0 ÷-4.9
|
Volume of a broad tank, l |
L models 2.0 and 2.5 | 0.5
|
Models of 3.0 l |
2001 vyp. | 0.45
|
2002 vyp. | 0.5
|
Heating of salon |
The maximum power of return of the heat exchanger (at a difference of temperatures of cooling liquid and the entering air in 65 °C and a consumption of liquid of 360 l/h), kW | 5
|
Air consumption in the mode of ventilation and maximum warming up, m3
| 300
|
The maximum consumption of air (heating is disconnected, the circulation mode, the 4th high-speed mode of the fan), m3
| 500
|
Sizes of the heat exchanger, mm | 193.5 ÷ 152 ÷ 35.0
|
Heater fan drive electric motor type | Magnetic, with a power not less than 200 W at supply voltage of 12 V
|
Fan type | Centrifugal (SIROCCO)
|
Sizes of a krylchatka (diameter of ÷ width), mm | 150? 75
|
Air conditioning system |
General parameters |
Oil coolant type | HFC-134a (CH2FCF3)
|
Volume of coolant, kg | 0.65 ± 0.05
|
Refrigerating capacity, kW | 5.2
|
Idling turns at included To/in (MPFI power supply system) | 850 ± 100
|
Compressor |
Compressor type | Rotary, with five shovels and with the fixed volume (DKV-14G)
|
Expense, cm3/turnover | 140
|
Maximum admissible frequency of rotation, rpm | 7000
|
Magnetic coupling of coupling |
Type | Dry, one-disk with the drive from a V-shaped belt
|
Type of a driving belt |
L models 2.0 and 2.5 | Mnogoruchyeva 4 PK
|
Models of 3.0 l | Mnogoruchyeva 6 PK
|
Power consumption, W | 38
|
Diameter of a driving pulley, mm | 125
|
Transfer relations of the belt drive | 1.064:1
|
Condenser |
Type | The multiline
|
Heat exchanger type | With corrugated plates
|
Area of a front surface of the heat exchanger, sq.m
| 0.22
|
Thickness of the heat exchanger, mm | 21
|
Effektivnaya Square of the heat exchanger, sq.m
| 6.52
|
Receiver dehumidifier |
Effective internal volume, cm3
| 250
|
Broad valve |
Type | With the built-in equalizer
|
Evaporator |
Type | The single-chamber
|
Sizes, mm | 235? 224? 60
|
Air supply fan |
Type | Centrifugal (SIROCCO)
|
Sizes (outer diameter of ÷ width), mm | 150 ÷ 75
|
Power consumption (at food in 12 V), W | 220
|
Sensor switch of pressure (two-level) |
Working pressure of operation of the low pressure sensor switch, kPa |
In C — Vykl | 177 ± 25
|
Vykl — Vkl | 216 1
|
Working pressure of operation of the high-pressure sensor switch, kPa |
In C — Vykl | 2942 ± 196
|
Overlap | 588 ± 196
|
Amplifier of thermocontrol |
|
Activation temperature (air at the exit from the evaporator) |
Efforts of a tightening of threaded connections, Nanometer |
|
Efforts of a tightening of threaded connections are given also in the text of the Head and on sopr. illustrations. |
|
Bolts of fastening of a cover of the thermostat | 6.4
|
Bolts of fastening of casings of fans of the cooling system | 4.9
|
Fastening bolts/nut a krylchatok of fans to electric motors |
L models 2.0 and 2.5 | 3.4
|
Models of 3.0 l | 7.5
|
Bolts of fastening of electric motors of fans | 4.4
|
Bolts of fastening of a radiator |
L models 2.0 and 2.5 | 18
|
Models of 3.0 l | 12
|
Bolts of fastening of a broad tank | 4.9
|
Bolts of fastening of lines of a path of cooling of ATF | 12
|
Boats of fastening of the water pump |
L models 2.0 and 2.5 |
First stage | 12
|
Second stage | 12
|
L models 2.0 and 2.5 | 6.4
|
Bolts and nuts of fastening of sections of a casing of a heater | 7.35
|
Bolts of fastening of the K/V compressor to basic arms | 28.9
|
Bolts of fastening of basic arms of fastening of the K/V compressor | 35
|
Bolts of fastening of a cover of a belt of the drive of the compressor | 7.4
|
Nut of fastening of a pulley of the drive of the K/V compressor | 23
|
Bolts of fastening of an arm of a tension roller of a belt of the drive of the K/V compressor | 23
|
Bolts of fastening of the condenser | 7.4
|
Screws of fastening of a receiver dehumidifier | 7.4
|
Nipple bolts of fastening of lines of a refrigerator path to the K/V compressor | 15
|
Nipple bolt of fastening of the line of a refrigerator path to a receiver dehumidifier To/in | 7.4
|